compared w/ FLUKE 715 788 787
Source/Output Step DC Volts, current, Frequency and measure Volts Amps Resistance Frequency, Temperture, can connect to RS232
Brand new with 1 year USA warranty + 14 days return policy
In stock in our USA warehouse, USA order ship by usps priority mail 2-3 business days with track number for free
FEATURES
1.Measurement V, mA, Frequency, Ω, Temperature, max count 40000.
2.Source output of voltage, current, frequency with high accuracy, voltage and current can increase by degrees in 0 to 99 steps to output step voltage and step current.
3.With PC photoelectricity interface and PC windows software to record data and export graph.
4.With measurement function and source output function, double display to show and control.
5.With 32 function button and numeric button,Source output can be set and modified directly by numeric button.
6.Output Power:15V 25mA
MS7221 Volt/mA Calibrator is a source and measurement tool. This Calibrator can be used in measurement or output 0 to 24 mA DC current loop, and 0 to 10 V DC voltage.
•Display: 40000 counts
•Measure loop current signals with very high accuracy of 0.015% and 1 uA resolution
•Measure voltage output process signals from PLCs, transmitters
•Source or simulate 24 mA loop current
•Source voltage to 100 mV or 10V
•24V loop supply with simultaneous current measurement
SPECIFICATIONS
DCV Measure:0 ~ 100m V, 0 ~ 10 V±0.02%
DCV Source:0 ~ 100m V, 0 ~ 10 V±0.02%
DCmA Measure(% of span):0 ~ 24 mA±0.015%
DCmA Source(% of span):0 ~ 24 mA±0.015%
Weight:350g (include battery)
Size:190mm × 89mm × 42mm
Battery:9VDC,006P or 1604
Specifications
General Specification
•Display : Max 40000
•Range: autorange
•Overload indication: “OL” on the LCD
•Reading Holding: on the LCD
•Power Supply: AA 1.5Vx 8 piece and 9V Alkaline type one piece
•Storage Temperature: -20℃~70℃
•Operating Temperature: 0℃~40℃
•Safety: Designed to ICE1010_1 300V CAT.Ⅲ
•Dimension Size : 224mm×172mm×59mm
•Weight : approx. 1100g (include batteries)
RS232 Data Interface
The instrument can transmit data to PC computer by a RS232 infrared photoelectricity interface in real-time mode. You can connect the RS232 interface to a serial port of PC computer, then install the user data record software into the computer according to the README.TEXT file in the SETUP disk. After that, you can record and print the measured data of the instrument in real-time mode on the WINDOWS. The user data record special software can complete to record, collate, plot, print data in real-time mode.
Note: In all measurement mode, the measured data can be transmitted to the PC serial port automatically, but the
instrument will stop transmitting in the SETUP mode.
Backlight
Low Voltage Indication
Accuracy and Resolution
Accuracy is given as ±(% of reading +number of least significant digits)at 18℃ to 28℃,with humidity up to 80%
Measurement·DC Volts
| RANGE | ACCURACY | RESOLUTION |
| 400.00 mV | 0.025%rdg+10d | 0.01mV |
| 4.0000 V | 0.025%rdg+5d | 0.1mV |
| 40.000V | 0.025%rdg+5d | 1mV |
| 300.00V | 0.025%rdg+5d | 10mV |
Max Overload Voltage: 400V (RMS)
Measurement·AC Volts RMS
| RANGE | ACCURACY | RESOLUTION |
| 400.00mV | 0.7%rdg+20d | 0.01mV |
| 4.0000V | 0.7%rdg+10d | 0.1mV |
| 40.000V | 0.7%rdg+10d | 1mV |
| 300.00V | 0.7%rdg+10d | 10mV |
Max Overload Voltage: 400V (RMS)
Measurement·DC Current
| RANGE | ACCURACY | RESOLUTION |
| 400.00mA | 0.1%rdg+10d | 0.01mA |
Overload Protection: 500mA/250V Fuse
Measurement·AC Current RMS
| RANGE | ACCURACY | RESOLUTION |
| 400.00mA | 0.7%rdg+10d | 0.01mA |
Overload Protection: 500mA/250V Fuse
Measurement·Resistance
| RANGE | ACCURACY | RESOLUTION |
| 400.00Ω | 0.1%rdg+10d | 0.01Ω |
| 4.0000kΩ | 0.1%rdg+10d | 0.1Ω |
| 40.000 kΩ | 0.1%rdg+10d | 1Ω |
| 400.00 kΩ | 0.1%rdg+10d | 10Ω |
Max Overload Voltage: 250V (RMS)
Measurement·Frequency
| RANGE | ACCURACY | RESOLUTION |
| 4Hz~999.9Hz | 0.05 | 0.01Hz |
| 100Hz ~5kHz | 0.5Hz | 0.01Hz~0.1Hz |
| 5kHz ~30kHz | 2Hz | 0.1Hz~1Hz |
Min Measurement Voltage: 50mV
Max Overload Voltage: 400V (RMS)
Measurement·Temperature
| RANGE | ACCURACY | RESOLUTION |
| -50℃~1300℃ | ±0.3%+1℃ | 0.1℃ |
Source·Voltage
| RANGE | ACCURACY | RESOLUTION |
| 100.000mV DC | 0.025%+0.03% | 1μV |
| 5.0000V DC | 0.025%+0.02% | 100μV |
| 15.000V DC | 0.025%+0.02% | 1mV |
Step time: 1~99 Step Cycle: 1~99s
Accuracy is given as ±(% of reading +% of range)
Source·Current
| RANGE | ACCURACY | RESOLUTION |
| 25.000mA | 0.02%+0.02% | 1μA |
Accuracy is given as ±(% of reading +% of range)
Source·Frequency
| RANGE | ACCURACY | RESOLUTION |
| 20Hz~5000Hz | 0.02% | 0.01Hz~0.1Hz |
18 standard frequency: 5kHz, 2500Hz, 2000Hz, 1250Hz, 1000Hz, 800Hz, 500Hz, 400Hz, 250Hz,
200Hz, 160Hz, 100Hz, 80Hz, 60Hz, 50Hz, 40Hz, 25Hz, 20Hz。
Shipping: USA order will ship from our USA warehouse, ALL ither orders will ship from our China warehouse by express mail with track number, it takes around 5-8 business days to arrive, thank you
Accessories
• Red/black banana test leads;<
Tell us what you think about this item, share your opinion with other people. Please make sure that your review focus on this item. All the reviews are moderated and will be reviewed within two business days. Inappropriate reviews will not be posted.
Have any question or inquire for this item? Please contact Customer Service. (Our customer representative will get back shortly.)